Cooling Tower Problems. Use Ecoclean 2300 for Descaling Sulphates.
Commercial properties cooling Tower and chillers must
work smoothly to keep these places cool & comfortable for the purpose of business.
The water that circulates in cooling Tower has four major problems.
These are :-
1. Biological Contamination.
2. Fouling
3. Scalling.
4. Corrossion.
Biological Contamination. As the place of Cooling Tower is always in a
bright sunlight naturally it is Hot & Humid as a result growth of unwanted
bacteria in water increases substantially. These bacterial growth is health
hazard to the people and are worse for the efficiency of the cooling Tower.
Fouling can occur at different
areas of your cooling tower system. The fill is one of the prime locations for
fouling to occur. Fouling is the clogging of cooling surfaces or pipes with
debris, dirt, and dust. When water cannot make it into and pass through the
fill as designed, the air is not cooled properly. This means that the system
has to work longer to achieve the same results. Which means it is using more
electricity.
Scaling. The main objective of
cooling Tower are to transfer heat from the chiller or from the particular area.
The scaling build up of Minerals in the water
creates layers which minimises the efficiency. The scaling of calcium
sulphates, Magnesium sulphates deposits on the surfaces. This scaling must be
removed or operating cost will increase.
Corrosion – Cooling towers and chillers that leak can many times be
attributed to cooling systems that are ignored. This can be especially
prevalent in cooling towers that use closed loop systems. When the air, sodium,
and other chemicals that are found in our water supplies are left unchecked to
run through a cooling tower system they eat away at the metal and will lead to
leaks.
Water
treatment along with chiller & cooling tower maintenance that involves
cleaning all of the heat exchange surfaces is the way to keep your commercial
HVAC system operating properly.
Water
treatment along with chiller & cooling tower maintenance that involves
cleaning all of the heat exchange surfaces is the way to keep your commercial
HVAC system operating properly.
Ecoclean
2300 helps to flocculate,Sediment,
Disinfect & Descale the water.
It is an effective
bio-pesticide against bacteria (including E-Coli).
It neutralises and
descal the salts of calcium and magnesium rendering the water soft.
All
these Cooling Tower water problems can be resolved by dosing Ecoclean 2300 in
Cooling Tower water.
Comments
Post a Comment